← D.C. Law 26-152 · All reviewed explanations

D.C. Law 26-152 · DC District of Columbia · Section 2

Single-staircase housing code rulemaking

When it was enacted

Enacted 2026-06-02 · Effective 2026-07-18 · Permanent law.

Official record dates

What this builds on

This section adds a multifamily-building definition and a new rulemaking mandate rather than directly replacing an identified earlier staircase-count provision. This review has not independently compared every existing construction-code egress requirement.

What this creates

Multifamily residential building means more than two dwelling units with primarily permanent occupants. The Department of Buildings must issue Construction Code amendments by July 1, 2027 to allow a single entrance and egress stairway to serve multifamily residential buildings described in the act as up to six stories above grade plane or high-rise buildings. For that clause, high-rise means an occupied floor more than 75 feet above the lowest fire-department vehicle-access level. In drafting rules, the Department must consider fire/smoke protection, including fire-resistive construction and adequate automatic sprinklers; safe/quick exit requirements, including maximum unit-door travel distance and preventing unit doors opening toward an interior exit stair; limits of no more than four units per floor or a commensurate floor-area limit; and relevant domestic/international best practices. These considerations do not limit later rulemaking authority once the initial mandate is satisfied.

Enacted source

In plain English

This directs the Department to change the code through rules; it does not itself issue a building permit. The listed safety items are mandatory considerations in drafting, not a claim that every listed design detail is already the final rule. The source uses both the six-story description and a separately defined high-rise category; the guide preserves that wording rather than treating six stories as an absolute limit for every category. Actual regulations, interpretations, permit conditions and later legal changes have not been verified.

Timing and applicability

Recorded effective date July 18, 2026. The rulemaking deadline is July 1, 2027; actual rules and individual project approvals remain unverified.

Explanation reviewed 2026-10-23.

Read the official section text
2 The Construction Codes Approval and Amendments Act of 1986, effective March 21, 1987 (D.C. Law 6-216; D.C. Official Code § 6-1401 et seq .), is amended as follows: (a) Section 2 (D.C. Official Code § 6-1401) is amended by adding a new paragraph (10A) to read as follows: (10A) "Multifamily residential building" means a building containing more than 2 dwelling units where the occupants are primarily permanent in nature. . (b) A new section 10f is added to read as follows: 10f Single staircase multifamily residential buildings. (a) (1) No later than July 1, 2027, the Department of Buildings shall promulgate rules amending the Construction Codes to allow for a single entrance and egress stairway to serve multifamily residential buildings up to 6 stories above grade plane or high-rise buildings. (2) For purposes of paragraph (1) of this subsection, the term "high-rise building" means a building with an occupied floor located more than 75 feet above the lowest level of fire-department vehicle access. (b) In drafting rules required pursuant to subsection (a)(1) of this section, the Department shall consider: (1) Requirements that prevent the spread of fires and smoke in such multifamily residential buildings, including requiring the use of fire-resistive construction, and requiring the provision of adequate automatic fire sprinklers throughout a building; (2) Requirements that enable occupants to safely and quickly exit such a multifamily residential building in emergency situations, including establishing a maximum travel distance from the exit or entry door of any dwelling unit to the exit stairway and prohibiting dwelling unit doors from opening in the direction of an interior exit stairway; (3) Requirements limiting such multifamily residential buildings to either no more than 4 units per floor or a commensurate limitation on square footage per floor; and (4) Any best practices in state, local, and international laws and codes that allow for the construction of multifamily residential buildings with a single entrance and egress stairway. (c) The considerations set forth in subsection (b) of this section shall not be construed to limit the Department's authority to promulgate or amend rules regarding multifamily residential buildings after satisfying the requirements set forth in subsection (a) of this section. Mar. 21, 1987, D.C. Law 6-216, § 10f .
Pinned official bulk source

Interpretations & later changes

Later-law and court review may be incomplete. Absence of an entry does not establish that the original provision remains in force.

No separately reviewed later development is published here yet.

Read the complete law guide and review status